According to the version, these resistance temperature sensors with display are designed for contact temperature measurement of gaseous, liquid and solid substances in various applications. The plastic head is equipped with a cable grommet or a connector; the measured temperature is indicated on the 4-digit display located under the transparent cap of the head. The temperature sensors with display are possible to be used for any control systems compatible with the MODBUS RTU communication protocol; the communication takes place through the RS 485 bus.

The standard temperature range for using of the temperature sensors with display is -50 to 150 °C. Within this range, the required operating temperature ranges may be programmed, while the minimum difference between the lower and upper limit of the temperature range is 10 °C. The maximum temperature around the head is -30 to 70 °C and must not be exceeded even for a brief period. The temperature sensors with display meet ingress protection IP 65 according to EN 60 529. The temperature sensors with display are easy to be installed thanks to the unique design of "S-head" made by SENSIT s.r.o. The temperature sensors are designed to be operated in a chemically non-aggressive environment, the use must be chosen with regard to temperature resistance of the head and the metal cases.

In terms of the location of temperature sensing element and the sensor use, the following versions are distinguished:

  • SDD 112A, SDD 112AK – for sensing the temperature around the sensor; the temperature sensing element is located in the metal stem of the length of 25 to 50 mm
  • SDD 122, SDD 122K – for sensing the temperature in air conditioning ducts and pipes; the temperature sensing element is located in the metal stem of the length of 70 to 420 mm; it comes with a plastic holder; the JS 130 tube or K120 metal holder can be provided as accessories
  • SDD 142, SDD 142K – surface design for measuring the temperature on surface of solids or pipes; the temperature sensing element is located in the metal case on the head bottom side; it is delivered with a fastening strap (length of 40 cm) and a cap
  • SDD 162, SDD 162K – for sensing the temperature in air conditioning ducts and pipes; the temperature sensing element is located in the metal stem of the length of 50 to 220 mm, whose part is a mounting screw

ACCESSORIES

  • Plastic holder (supplied with SDD 122)
  • JS 130 stainless steel thermowell – for SDD 122
  • K 120 metal holder – for SDD 122
  • Thermal paste up to 200 °C, 5 g – for SDD 142
  • led-in connector ELKA 4012 – for all of the types
  • connection cables with RKT direct connector, or rectangular RKWT connector – for all of the types
  • screw with collet or cutting rings – if different lengths of stem immersion of the temperature sensor are set  

DECLARATION, CERTIFICATION, CALIBRATION

  • EC Declaration of Conformity – in accordance with Act 22/1997 Coll. on technical requirements on products as amended.
  • Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard) or in an Accredited laboratory.  

 

 


  • Specifications
  • Download
Basic information
Communication features
Communication via RS 485, protocol ModBus RTU
Maximal segment length is 1 200 m
247 modules / 1 serial port
Present transfer speed 9600 Bb
Type of sensing element Pt 1000/3850, accuracy class B (± 0.3 + 0.005 x | t | ) in °C
Measuring range
adjustable
Max. temperature range -50 °C to 150 °C
Measurement error
0.8 % from the range, at least 0.5 °C
Display screen 4-digit, LED, character dimension 7.62 × 4.22 mm
Supply voltage U 15 to 30 VDC
Nominal voltage Un 24 V DC
Load resistance > 50(U - 14)Ω > 50 kΩ
Material of the head
POLYAMID
Dimension of the head 70 x 63 x 34 mm
Wire cross-section 0.35 až 1.5 mm2
Ingress protection
IP 65 in accordance with EN 60 529
Cable connection Through the grommet M 16 × 1.5 / through the connector LUMBERG M12
Ambient temperature around the head -30 to 70 °C
Electric strength 500 V / 50 Hz in accordance with EN 60 730-1

SDD 112A, SDD 112AK
Length of the stem
50 mm
Diameter of the stem
6 +0,2 mm
Material of the stem
stainless steel DIN 1.4301
Insulation resistance min 200 MΩ at 500 VDC, at the temperature from 15 °C to 35 °C and at maximum relative humidity of 80%
Maximum measurement range -30 to 70 °C

SDD 122, SDD 122K
Length of the stem
70, 120, 180, 240, 300, 360 and 420 mm
Diameter of the stem
6 +0,2 mm
Material of the stem
stainless steel DIN 1.4301
Insulation resistance min 200 MΩ at 500 VDC, at the temperature from 15 °C to 35 °C and at maximum relative humidity of 80%
Maximum measurement range -50 to 150 °C
by using a sensor with a longer stem of 60 mm, the upper limit of allowable temperature can be extended up to 250 °C

SDD 142, SDD 142K
Material of the case
brass
Material of the protective case
POLYAMID
Insulation resistance min 200 MΩ at 500 VDC, at the temperature from 15 °C to 35 °C and at maximum relative humidity of 80%
Maximum measurement range -30 to 110 °C

SDD 162, SDD 162K
Length of the stem
50, 100, 160 and 220 mm
Diameter of the stem
4 +0,2 mm
Material of the stem
stainless steel DIN 1.4301
Thread
G 1/2", M 20 x 1.5
Insulation resistance min 200 MΩ at 500 VDC, at the temperature from 15 °C to 35 °C and at maximum relative humidity of 80%
Maximum measurement range -50 to 110 °C

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

Test report - EN 61 373
Test report - EN 61 373Test report - EN 61 373
Test report - EN 50 155
Test report - EN 50 155Test report - EN 50 155