extend Your senses
sitemap
cz en
A selected group of goods  Products »

TEMPERATURE SENSORS UP TO 400 °C WITH PROGRAMMABLE CONVERTER 4–20 mA

Description and application

TEMPERATURE SENSORS UP TO 400 °C WITH PROGRAMMABLE CONVERTER 4–20 mA

These resistance-type sensors are intended for contact measurements of temperatures up to 400 °C. Temperature sensors, in combination with a central holder or thermowell, can be used to measure the temperature in various applications of an industrial environment. The sensor variant with welded thread is ideal for direct measuring of mediums in ducts. The standard operating temperature range is -50 to 400 °C. The sensors can be utilised for any control systems that are compatible with output signal 4–20 mA.

The sensors are designed to be operated in a chemically non-aggressive environment.

ACCESSORIES

DECLARATION, CERTIFICATION, CALIBRATION

  • EC Declaration of Conformity – in accordance with Act 22/1997 Coll. on technical requirements on products as amended.
  • Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard) or in an Accredited laboratory.  

 


  • Specifications
  • Wiring diagram
  • Dimensional draft
  • Download

Sensor type with smooth stem
Sensor type with welded-on screwing
PTS 81
PTS 91
Type of sensing element Pt 100
Output signal 4 to 20 mA
Maximum measurement range -50 to 400 °C
Adjustable measurement range optional, minimum interval 10 °C
Accuracy of sensing element class B according to IEC 751
Accuracy of converter temperature error < 0.05 °C
error of setting < 0.12 °C
error of linearity< 0.05 % from the set range, minimum 0.16 °C
influence of supply voltage < 0.005 %/V from the range
Current limitation sensing element < 3.2 mA
sensing element break > 22.7 mA
Lead-in connection recommended 1.5 to 2.5 mm2
Ingress protection IP 54 according to EN 60 529
Material of sensor stem stainless steel DIN 1.4301
Standard length of the stem L1 50, 100, 160, 220, 280, 400 mm
Nominal pressure of the stem PN 63 (with a screw point)
Way of programming PK - USB adapter *
Thread types by PTS 91 G 1/2"; M 20 x 1.5; M 27 x 2
Insulation resistance > 200 MΩ at 500 V DC, 25 °C± 3 °C; humidity < 85 %
Material of connection head aluminium, LIMATHERM B
Operating conditions ambient temperature: -25 to 80 °C
relative humidity: max 100 % (at the ambient temperature 25 °C)
atmospheric pressure: 70 to 107 kPa
Mass approximately 0.25 kg

* programming software is free

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

Datasheet - TEMPERATURE SENSORS UP TO 400 °C WI
Datasheet - TEMPERATURE SENSORS UP TO 400 °C WIDatasheet - TEMPERATURE SENSORS UP TO 400 °C WI
Schéma zapojení
Rozměrový náčrt

Back to category